Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 129-135, 2023.
Article in Chinese | WPRIM | ID: wpr-992816

ABSTRACT

Objective:To study the value of sound touch elastography (STE) linear combined with ultrasound score (US) in the diagnosis of chronic hepatitis B (CHB) liver fibrosis, and to investigate whether their combination can improve the diagnostic efficiency of subdividing the degree of CHB liver fibrosis. Furthermore, a comparison with STE linear combined with the serological model was performed to seek the optimal linear combination model.Methods:A total of 313 subjects were enrolled from September 2018 to December 2021 in Shenzhen Third People′s Hospital Affiliated to Guangdong Medical University, including 259 patients with CHB who had completed liver biopsy and 54 healthy volunteers. CHB patients were divided into liver fibrosis group (F1-F4 group) according to METAVIR classification standard, and healthy volunteers were used as the control group. All subjects underwent liver ultrasound examination, STE and blood biochemical indexes of liver function. The US was performed according to the liver ultrasound examination, and the liver stiffness measurement (LSM) was measured by STE, aspartate aminotransferase and platelet ratio index (APRI) was calculated by blood biochemical index. Fisher discriminant analysis was used to establish the linear combination (LC) diagnostic marker of US and LSM, and the linear combination (LC2) diagnostic marker of LSM and APRI, successively. Spearman rank correlation coefficient was used to analyze the correlations between US, LSM, APRI, LC2, LC and pathological results. The ROC curves of US, LSM, APRI, LC2 and LC for diagnosing CHB liver fibrosis were plotted, and the diagnostic efficiency of above diagnostic markers was evaluated according to the accuracy, sensitivity, specificity and area under the ROC curve (AUC).Results:The formula for the linear combination of US and LSM was LC=0.986 0×US+ 0.166 7×LSM, and LC was highly positively correlated with pathological findings ( rs=0.851, P<0.001), higher than US, LSM, LC2 and APRI ( rs=0.825, 0.775, 0.802, 0.586, all P<0.001). LC showed the best diagnostic efficiency. The AUCs for diagnosing ≥F1, ≥F2, ≥F3 liver fibrosis and =F4 cirrhosis were 0.945, 0.911, 0.954, 0.955, respectively, which superior to the AUCs of US (0.913, 0.879, 0.934 and 0.916, respectively), the AUCs of LSM (0.860, 0.871, 0.934 and 0.952, respectively) and the AUCs of LC2(0.899, 0.883, 0.941, 0.946, respectively). Compared with US, the AUC of LC diagnosis of ≥F1, ≥F2, ≥F3 liver fibrosis and =F4 cirrhosis increased by 3.2%, 3.2%, 2.0% and 3.9%, respectively, with all significant differences ( P<0.05). Compared with LSM, the AUC of LC increased by 8.5%, 4.0%, 2.0% and 0.3%, respectively, with significant difference ( P<0.05) except for stage =F4 cirrhosis.Compared with LC2, the AUC of LC increased by 4.6%, 2.8%, 1.3% and 0.9%, respectively, and there were significant differences in the diagnosis of ≥F1 and ≥F2 liver fibrosis ( P<0.05). Moreover, the overall efficiency of LC2 was not significantly improved than LSM, the difference was not significant ( P>0.05). Conclusions:US, LSM, LC2 and LC can be used to diagnose the degree of CHB liver fibrosis, but LC is better than US or LSM and LC2 alone, especially in the subdivision of mild liver fibrosis, which is a promising new diagnostic marker to subdivide the degree of CHB liver fibrosis.

2.
Organ Transplantation ; (6): 103-2021.
Article in Chinese | WPRIM | ID: wpr-862783

ABSTRACT

Objective To explore the value of ultrasound elastography in the non-invasive monitoring of liver elasticity of stable recipients at different stages after liver transplantation. Methods Clinical data of 73 stable recipients after liver transplantation were collected. According to the time after liver transplantation, all patients were divided into the early group (n=25) and medium-to-long group (n=48). In addition, 38 healthy subjects were assigned into the control group. The ultrasound indexes and liver function indexes were statistically compared among each group. The ultrasound elastography indexes of liver and spleen were analyzed, and their correlation with liver function indexes was analyzed. Results Compared with the control group, the ultrasound indexes, alanine aminotransferase (ALT), γ-glutamyl transferase (GGT) and alkaline phosphatase (ALP) levels were significantly increased in the early group (all P < 0.05), and the ultrasound indexes in the medium-to-long group were significantly increased, whereas the GGT level was significantly decreased (all P < 0.05). Compared with the early group, the right oblique diameter of liver, ALT, GGT and ALP levels were significantly decreased in the medium-to-long group (all P < 0.05). Compared with the control group, the sound touch elastography (STE) and sound touch quantify (STQ) values of liver and STE value of spleen in the early group and medium-to-long group were significantly increased (all P < 0.05). Compared with the early group, the ultrasound elastography indexes of liver and spleen in the medium-to-long group were remarkably decreased (all P < 0.05). The ultrasound elastography indexes of liver were weakly correlated with the ALT, aspartate aminotransferase (AST) and GGT levels, significantly correlated with ALP level. The STE value of spleen was weakly correlated with the ALP level. The STE value of liver was significantly correlated with the STQ value of liver. The STE and STQ values of liver were weakly correlated with the STE value of spleen. Conclusions The characteristics of liver elasticity in stable recipients after liver transplantation are various among different stages. Persistent monitoring of liver elasticity may provide a novelnon-invasive monitoring method during follow-up after liver transplantation.

3.
Chinese Journal of Ultrasonography ; (12): 812-817, 2021.
Article in Chinese | WPRIM | ID: wpr-910125

ABSTRACT

Objective:To explore the clinical application value of sound touch elastography (STE) in the evaluation of the curative effect of acupuncture and moxibustion in the treatment of stroke patients with upper limb spasm.Methods:Fifty-five patients with upper limb spasm after stroke were selected as stroke group, and thirty healthy volunteers matched with age, gender and body mass index (BMI) were selected as control group between September 2020 and March 2021. The shear wave velocity (SWV) of biceps brachii and triceps brachii were measured in both groups. In stroke group, the SWVs of biceps brachii and triceps brachii on spastic side and non-spastic side were measured before and after acupuncture treatment, and the correlations between SWV and spastic grade (X), muscle response angle (R1), passive range of motion (R2), spastic angle (R2-R1) of modified Tardieu scale (MTS) were analyzed.Results:At 0 degree, the SWV of spastic biceps brachii (3.85±0.62)m/s was significantly higher than those of the non-spastic side [(3.34±0.35)m/s] and control group [(3.15±2.66)m/s] (all P<0.001), and decreased [ (3.45±0.47)m/s] after acupuncture treatment ( P<0.001). At 90 degree, the SWV of non-spastic biceps brachii was larger than those of spastic side and control group [1.98(1.92, 2.14)m/s vs 1.98(1.92, 2.11) m/s, 1.95(1.86, 2.05)m/s, all P<0.05], and there was no significant difference between the SWV of spastic side and control group ( P>0.05). There were no significant differences in SWV of triceps brachii between the spastic side and control group at both 0 degree or 90 degree ( P>0.05). At 0 degree, SWV positively correlated with MTS (x) ( rs=0.639, P<0.001) and negatively with R1 ( rs=-0.527, P<0.001) and R2 ( rs=-0.825, P<0.001) on the spastic biceps brachii. Conclusions:STE can provide quantitative index for the objective evaluation of the curative effect of acupuncture in upper limb spasm after stroke, and it is proposed to be an effective means of clinical diagnosis and efficacy evaluation in patients with upper limb spasm after stroke.

4.
Chinese Journal of Ultrasonography ; (12): 617-620, 2019.
Article in Chinese | WPRIM | ID: wpr-754848

ABSTRACT

Objective To assess the applicability of sound touch elastography ( ST E) and sound touch quantify ( ST Q ) in measuring liver and spleen stiffness . Methods One hundred and eighteen healthy volunteers were included and underwent ST E and ST Q . T he success rate ,variability and reproducibility of ST E and ST Q were analyzed . T he accurate sampling size and number of tests for liver ST Q were also analyzed . Results T he success rates ,variability ,reproducibility of ST E and ST Q in liver were 97 .5% and 99 .2% ,8 .7% and 12 .0% ,0 .917 and 0 .916 , respectively . While those with spleen were 76 .3% and 66 .9% ,12 .4% and 16 .4% ,0 .847 and 0 .706 ,respectively . The sampling size of 1 .5 cm×1 .0 cm yield the lowest variability ( 8 .5% ) ( F =6 .562 , P =0 .002) ,and there was no significant difference between results of detecting 5 times and 10 times( P =0 .571) . T he liver and spleen stiffness of ST E were 5 .75 kPa ( 95%CI :5 .60-5 .91 kPa) and 15 .58 kPa ( 95% CI :14 .99 -16 .16 kPa) . Conclusions The measurement of liver stiffness using both ST E and ST Q have a high success rate and low variability . However ,ST E is better than STQ in measuring spleen stiffness .

SELECTION OF CITATIONS
SEARCH DETAIL